In some time zones the configured time for cameras recording with VRM is
one hour off.
Manual Recording in Operator Client for Local Storage and VRM starts recording for the
configured post-alarm time, for NVR cameras it starts recording until the manual recording button
is pressed again or until the configurable maximum manual recording time has elapsed.
NVR Archive Player requires no logon. No permissions for audio and video can be checked.
Permissions to export recording overrides restrictions to playback only time-sections of a camera.
The date and time in emails sent upon alarms are in UTC time format.
When calling up a camera through a decoder keyboard on an Allegiant monitor through Bosch
VMS, permissions are not considered.
When configuring a Workflow alarm, do not use links containing an URL.
When limiting access to video for certain schedules or the last N hours for Dual Authorization
groups, the value of the first logged on user is used.
When permissions for cameras are removed, cameras shown in Image windows before the
permissions have been revoked must be closed manually.
When the user of Configuration Client scans an existing VRM, the encoder names are renamed
to default BVMS names.
When using Find Video By Event, alarm recordings triggered by users cannot be found directly.
You need to search for the general alarm recording and then sort by user.
When using the Bosch VMS SDK to handle alarms,
o make sure to clear accepted alarms,
o if your application is disconnected from Bosch VMS, make sure to handle them after your
re-connected again,
o make sure to check the status of an alarm before you accept, un-accept or clear it.
When using the Initial Device Scan to assign new IP addresses for new devices, make sure to
not configure duplicate IP addresses.