Barco RS232 Bedienungsanleitung Seite 31

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 171
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 30
2. Basic Commands
Returned Data
Data [0] = Maximum Brightness value
Example
Reads the Maximum Brightness value of the projector, the awnser being \x64
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x27
Command[1]
\x02
Checksum
\x30
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x27
Command[1]
\x02
Data [0]
\x64
Checksum
\x8e
Stop
\xff
2.7.13 Saturation increment
Description
Increments the saturation by one.
Command
Command [0]
\x22
Command [1]
\x03
2.7.14 Saturation, decrement
Description
Decrements the Saturation by one.
R5976884 RLM SERIES 04/04/2006
29
Seitenansicht 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 170 171

Kommentare zu diesen Handbüchern

Keine Kommentare